Elimination of interference such as horizontal stripes, twill, vertical stripes, image blur, ghosting, etc.

Elimination of interference such as horizontal stripes, twill, vertical stripes, image blur, ghosting, etc.


Horizontal stripes, twill, vertical stripes, image blur, ghosting, etc. are basically caused by adjacent frequency interference, but their causes are different.

The horizontal stripes, twill, and vertical stripes are due to the large difference in the level values ​​between the channels. Generally, the difference is greater than 20DB, which will easily cause this type of interference. Therefore, the elimination method basically adjusts the level values ​​of all channels to be similar. For example, based on 75DB, the highest level does not exceed 80DB, and the lowest level is not lower than 70DB. In this adjustment, this type of interference can be eliminated (in this process, the field strength meter needs to be used for level measurement).

Image blurring and ghosting are caused by the low isolation between channels when channels are mixed. It may be caused by the direct connection without using the distribution splitter, the complete contact of the shielded mesh layer at the joint, the damage of the distribution splitter, etc. The method of elimination is to use the through-head for joint connection and merge with the qualified distribution splitter. New transmitters, etc.
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn

Variable Peristaltic Pump

Variable Peristaltic Pumpis a peristaltic dosing pump that can distribute many types of liquids, such as water-based liquid/shampoo/sauce/chemical-based liquid, etc.

The flow rate of the industrial variable speed Peristaltic Pump can be adjusted by the digital knob to adjust the motor speed to achieve the effect of adjusting the flow rate

The liquid only gets in touch with the Peristaltic Pump Tubing, will not cause cross-contamination. it's suitable for Liquid transfer occasions with high cleanliness requirements, Eg. : food/beverage/cosmetic/medical/biopharmaceutical...

For the Peristaltic Pump Tubing, We have different material choices for your various liquids. The standard tube is silicon tubing which conforms to the FDA certificate. Except that we also offer the Saint-Gobain imported tubing, Eg.: Norprene®A-60-F/Norprene®chemical /Pharmed® BPT... Which suitable for various chemical-based liquid.

Suitable for various industrial applications.

Variable Peristaltic Pump,Intelligent Programmable Pump,Dosing Peristaltic Pump,Timed Quantitative Pumps

Baoding Chuangrui Precision Pump Co., Ltd. , https://www.chuangruipump.com

Posted on