At 9:00 on May 17th, 2018, the Zhejiang Provincial Higher People's Court in the hospital the second court hearing the Hangzhou Intermediate People's Court accused Mo Huan Jing fire, theft (appeal) case. The staff of the community property service companies and the four firefighters involved in fire fighting were notified by the court to testify in court.
During the trial, the defender made several requests.
If relevant firemen and property staff are notified to appear in court to testify,
To obtain information on the property planning, nature of property rights and approval documents for fire inspection acceptance of the affected community.
Organize Mo Huanjing’s application for recognizing the site and re-inspecting the location of the hammer head tapping glass,
And the prosecutor submitted an application for the explanation of the cause of death of the four victims in the case during the trial and obtained the consent.
Japan uses a 20- year copper water Pump adapter.
The trial mainly focused on the following aspects:
First, the whole process of firefighting and rescue was restored to see whether Mo Huanjing followed the same floor and cooperated with the fire department to extinguish fire to prove whether Mo Huanjing had surrendered himself to the plot.
The second is the details of the fire department in the process of extinguishing the fire to demonstrate whether the fire extinguishing has any problems.
Third, it was found that if a person was trapped, it was after the arrival of the fire or after the open flame was extinguished to prove that the fire command had no responsibility.
Fourth, the lack of water and water pressure in the indoor fire hydrant system during the fire extinguishing process has affected the fire extinguishing process to prove whether there is any fault in the fire supervision and property.
The trial is currently under way. Specific details will not be known until the conclusion of the trial. The author conducts a preliminary analysis of the morning trial.
First, Mo Huan-jing picks up his own crimes and deserves it, but he also tells us that -
All of the blue nanny of the blue Qianjiang community in Hangzhou walked on to the arson. This has no way to return. Although she is related to her knowledge structure, social cognition and social status, she has to rely on stealing the employer's home to gambling on her way. Items and the fraud of the employer’s trust and constant borrowing of money eventually led her to fraudulently swindle her employer’s money by means of arson because of her inability to pay back the money. However, the individual’s inability to learn was inadvertently overestimating the fire’s danger and his ability to save fire. This led to an out-of-control situation, resulting in four mothers and sons burying themselves in the flames of the sea. Their sins are extremely difficult. They believe that the law will eventually impose penalties on her ignorance and greed, and eventually she will embark on a road to penitence. Ming Ge just wanted to tell everyone that there are two things to do with gambling. If you stick to it, it means no return. In the end, it is inevitable that you will lose your reputation.
II. Oversight of property management, property management and fire management not in accordance with operating procedures, causing major losses
Hangzhou Qianjiang blue extinguishing process arson, the fire department 5:11, that is, to reach the fire area, with access to the connected water search and rescue and fire-fighting process, the lack of water pressure, resulting in delay in extinguishing process, stop search and rescue personnel, fire team had to take various measures to water supply, water and finally had their own connection to the 18th floor fire from a ground floor, where a large delay time of the fire and rescue, fire spread and the property has an inescapable responsibility. Let's take a look at Zhejiang Provincial High Court's morning briefing:
The inspector checked the situation of Wang Moumou leading the firefighters to the pump room, why the fire pump was in the manual open state on the day of the incident, and then instructed the staff to inquire about the operation process of the fire pump.
Wie witness testified that at 5:10 on June 22, 2017 pay would, after learning its 18th floor 2 1 unit on fire, the fire pump will be turned on manually from the property Wangjing according to instructions to go see if the fire pump running, Change to automatic.
The inspector had questions on the normal start-up conditions of the fire pump, automatic start-up and manual start-up, operation after entering the pump room, why the pump was not manually controlled in the pump room, and the water pressure change after the pump was running. Ask Wei.
The collegial panel checked Wei's understanding of the starting fire pump operation mode and the current operation process, and why the fire pump was considered normal.
Wei answered the above question, saying that after receiving the telephone notice, after more than ten minutes rushed to the pump room, the starting status of the water pump was changed from manual opening to automatic opening.
Japanese stainless steel fire hydrant interface has been installed for 3 years.
After the fire, consumer control room staff on duty in the fire hydrant pump control switches do not have the manual mode, the fire hydrant pump does not start in time after 5:07 fire confirmation;
After 5:40 the scene firefighters button is pressed hydrant, fire hydrant pump has not yet started.
After 5:44 hydrant pump starts, the water supply network is not significantly increased, can not meet the requirements of fire.
The fire hydrant pump adapter used was rusted. The fire truck could not supply water through the adapter to the building's pipe network. It relied only on the roof tank and could not meet the long-term continuous water supply and fire extinguishing needs. The water gun pressure was insufficient.
In other words, the entire indoor fire hydrant system is in an unusable state, and ultimately it is up to the fire brigade to lay fire hoses downstairs downstairs to save the fire. This delayed a large amount of time, and it was difficult for people to accept the prolonged delay of nearly one hour.
As Greentown Group, one of China's top 10 real estate companies, its Greentown property is such a management level that people are inevitably skeptical about the current fire safety and other management standards of Chinese property companies.
Third, what lessons should be learned by the fire department, what to do?
A classic old saying goes: It only takes a long time to know who is nude. For the fire supervision and management, something went wrong to know what problems existed in the management level.
Whether we admit it or not, in the case of the Hangzhou Blue Qianjiang nanny arson, from the perspective of the problems reflected in the subsequent accident investigation, our current fire supervision and management and fire fighting and rescue capabilities need to be improved. So, what should we do about this issue?
(a) Fire prevention.
Judging from the case, residential property is generally not a key unit of fire safety and should be supervised by the local police station. The fire department management is the fire protection audit, acceptance, daily supervision and management, handed over to the local police station management, the fire department is only to conduct business guidance.
Then, the supervisory staff of the fire department will be instructed to record the business guidance of the local police station, as well as the status of fire inspection and acceptance. In this fire, they will be questioned.
From the situation that the corrosion of the hydrant system pump adapter described in the trial could not be used, the community should be used for a short period of time. It should not be a problem through fire inspection and acceptance.
That is to say, in the fire supervision and management, besides how to fill out the business guidance record of the police station, it is the test that the fire department must face.
We hope that our fire department in Hangzhou will provide corresponding business guidance to the local police station. Otherwise, there is no guidance for the police station, and the fire department's dereliction of duty is inevitable.
(b) Fire safety in police stations.
Judging from the current situation, the Greentown property responsible for the Blue Qianjiang Community has the following problems in fire management:
1 , property inspection inspection records afterwards fill. After the fire broke out, the property related personnel fill in some fire equipment inspection records;
2. The fire truck passage is blocked. Fire lanes are covered by greening, affecting the passage and parking of fire-fighting vehicles;
3 , fire control room staff physical evidence posts. At the time of the fire, one of the staff on duty in the control room did not obtain the occupational qualification certificate for the firefighters of the building and construction.
4 , the operating procedure error. When the fire broke out, the control switch of the fire hydrant pump in the pump room was not in the manual state, instead of being in the automatic state, requiring the personnel to go down to the pump room to turn to the automatic state. The fire pump room also had no on-duty personnel (if unattended, there should be someone On duty, otherwise the control switch should be in automatic state).
5. There is no difference between the indoor fire hydrant system and the surrounding environment. The indoor fire hydrant door was decorated with marble and it was partially opened inconvenient.
6 , the building pump adapter corrosion can not be used. This is a problem of daily management and maintenance. The water pump adapter can be rusted and unusable. It can be seen that the property lacks attention and extreme attention to fire management and maintenance. Corporate conscience should be tortured.
The above problems, as long as the police station normal inspection, it is possible to find problems, but this problem has even existed, the dispatch of fire management in the area, there is suspicion of malfeasance.
Japan has installed 40 years of copper pump adapters.
(3) Whether there is a problem with fire-fighting and rescue has yet to be confirmed.
The fire, the local command center 119 5:04:50 Alarm, 5:07 dispatched fire engines and rescue,
5:11:16, the first car to reach the property cell door.
5:40 day, firefighters from the fire hydrant pump button press,
5:44, fire hydrant pump start, but still non-pressure pipeline network, roof water tanks only last a short time.
Video display cell, 5:54, the scene has not yet started laying of water, after the laying of the water 18 to the water layer begins to fire,
Is about 6:15, the fire under control after the scene.
Official Journal: 6:48, live fire was extinguished. At about 7 o'clock, the firefighters discovered four trapped persons, immediately carried out vital signs examinations and conducted cardiopulmonary resuscitation, and reported that the headquarters required medical personnel and stretchers to go upstairs.
7:05, firefighters will be transferred to the trapped elevator room. Subsequently, the personnel were transferred to the lower floors and handed over to the medical staff.
If this is really the case. Our fire fighting has more or less many problems.
One is that the squadron in the area did not have a clear grasp of the “six familiars†of the community, which caused the fire truck to arrive at the wrong place. After turning around and cutting the iron lock of the gate, the fire lane was used to enter the site.
One is to use the roof water tank to cover and save people without success.
And a confirmation acknowledgment indoor fire hydrant was dry process, took too long, from 5:40 pumping up button is pressed, the 0615 has been laid fire hose, subjected to 35 minutes, and in this situation the art trapped (Wu, Huang Moumou testified that 5:17, they ride in the elevator to the 17th floor to lead the security, that the room was, that is, no later than the 5:20, the fire department had been informed Some people are trapped.)
An accidental arson caused four innocent deaths. It is regrettable that people feel sorry, but also allow people to think deeply. This vicious arson case caused such a large loss, reflecting the greed and ignorance of the defendant Mo Huanjing, reflecting the well-known Greentown property fire management status, and also reflecting the loopholes in local law enforcement supervision.
Japan's copper pump adapter has been installed for 40 years.
Hopefully, people can change the notion of "fire safety, saying it's important, forget about it, and don't do it." Lu Xun had a special name for this kind of understanding, called "silver-like guns." He hopes that such "silver-like guns" will not appear again in the future, especially when it comes to public safety fire prevention. And control.
This article is reproduced from WeChat public number: Mingge said fire.
Oil drilling hydraulic power tongs, wellhead tools
Hydraulic casing power tongs, hydraulic drill pipe power tongs, hydraulic tubing power tongs, hydraulic sucker rod power tongs.
The power tong is an ideal wellhead tool for oil drilling, which is widely used in the threading operation of the pipe string in the offshore and land drilling and workover operations. The use of this pliers can play the role of safety, labor saving and improving work efficiency. This series of pliers is an open type, can freely release the pipe string, and has strong maneuverability; it integrates torque pliers and rotary pliers, and the upper and lower pliers replace cat head, hanging pliers and rotary rope. The power tongs conform to the SY/T5074 standard.
The oil drilling and production wellhead mechanized tools developed by the company have many varieties and complete specifications, and have formed more than 50 series, including ZQ drill pipe power tongs series, TQ casing power tongs series, XSL rotary faucet series, etc., and more than 100 series The product structure of specifications, sales cover all major oil fields in the country as well as Europe, America, the Middle East, Central Asia, Southeast Asia and other regions.
Hydraulic Power Tongs,Hydraulic casing power tongs, hydraulic drill pipe power tongs, hydraulic tubing power tongs, hydraulic sucker rod power tongs
Rugao Yaou Import & Export Trade Co., Ltd , https://www.ntyaous.com